Mortuary Refrigerator

Mortuary Refrigerators (also known as mortuary coolers or dead body refrigerators) provide secure and efficient storage for deceased bodies. These refrigeration units are designed to maintain a stable and appropriate temperature for preserving remains, ensuring they remain in optimal condition until further handling is required. Whether for use in hospital morgues, funeral homes, or mortuary facilities, our mortuary coolers and mortuary freezers offer a reliable solution to prevent decay, maintain dignity, and ensure sanitary storage.

Stainless steel mortuary corpse refrigerators are mainly used in hospital morgues, funeral parlors and other places to freeze and preserve corpses to ensure that the remains are preserved at a suitable temperature to avoid decay and deformation of the remains to maintain the dignity of the deceased.

Mortuary Refrigerator Models and Dimensions

Model Capacity Overall Dimensions, L × W × H Internal Chamber Dimensions Body Tray Size Load per Chamber
APS-MR1 Single-Body Mortuary Refrigerator 1 body 2530 × 800 × 720 mm 1950 × 640 × 450 mm 1950 × 610 mm 150 kg
APS-MR2 Two-Body Mortuary Refrigerator 2 bodies 2530 × 850 × 1300 mm 1950 × 640 × 450 mm 1950 × 610 mm 150 kg
APS-MR3 Three-Body Mortuary Refrigerator 3 bodies 2530 × 850 × 1800 mm 1950 × 640 × 450 mm 1950 × 610 mm 150 kg
APS-MR4 Four-Body Mortuary Refrigerator 4 bodies 2530 × 1580 × 1300 mm 1950 × 640 × 450 mm 1950 × 610 mm 150 kg
APS-MR6 Six-Body Mortuary Refrigerator 6 bodies 2530 × 1580 × 1800 mm 1950 × 640 × 450 mm 1950 × 610 mm 150 kg
APS-MR8 Eight-Body Mortuary Refrigerator 8 bodies 2530 × 1580 × 2150 mm 1950 × 640 × 450 mm 1950 × 610 mm 150 kg
APS-MR9 Nine-Body Mortuary Refrigerator 9 bodies 2350 × 2520 × 1800 mm 1950 × 640 × 450 mm 1950 × 610 mm 150 kg

Model dimensions and chamber capacities are taken from the corresponding product pages. The factory’s latest technical data sheet and general arrangement drawing should be used for final order confirmation.

Application-Specific Purchasing Priorities

Although the underlying equipment is similar, different buyer types weigh the evaluation criteria above differently:

  • Hospital morgues prioritize fast turnover and rigorous sanitation — SUS304 stainless steel, smooth-draining chamber interiors, and independent chamber control (so one chamber can be serviced without shutting down the whole unit) matter most here.
  • Funeral homes prioritize dignity and quiet, reliable operation in a client-facing environment — sliding tray systems for gentle handling, low-noise refrigeration, and a consistent 2°C–8°C holding temperature are the deciding factors.
  • Forensic institutes, teaching hospitals, and medical examiner offices prioritize extended, multi-week storage windows and full alarm/monitoring coverage — temperature deviation, door-open, and power-failure alerts — because remains may stay in custody far longer than in a standard funeral workflow.
  • Government tenders and disaster-response procurement prioritize documentation (CE certificates, technical drawings), rapid delivery, and higher-capacity multi-chamber configurations that can be deployed on short notice.

Identifying which of these profiles a buyer falls into, before requesting a quotation, usually shortens the sourcing cycle by several rounds of back-and-forth.

Installation and Space Planning

Before placing an order, most facilities need to confirm three things on-site: door and corridor clearance for delivery and future servicing, a stable power supply matching the unit’s voltage and frequency, and floor drainage or a level, load-bearing surface suitable for the unit’s operating weight. None of these are unusual requirements, but confirming them before shipment — rather than after the unit arrives — is what prevents installation delays. Our team can work from floor plans or photos of the intended installation area to flag any clearance or electrical issues in advance.

Maintenance and Long-Term Operation

A mortuary refrigerator is a heavy-duty appliance, not a set-and-forget one. Routine upkeep is straightforward but should be scheduled rather than reactive: door seals should be inspected periodically for wear, since a failing seal is one of the most common causes of temperature drift; chamber interiors should be cleaned and disinfected between uses following the facility’s own hygiene protocol; and the refrigeration system benefits from periodic checks of the compressor and condenser, particularly in high-ambient-temperature climates. Facilities that follow this kind of schedule typically get the full service life out of the unit before any major component needs replacement.

Special Requirements: Bariatric and Oversized Bodies

Standard trays are rated to 150 kg per chamber — sufficient for the large majority of cases, but not for every facility. Where bariatric storage is a recurring requirement rather than an exception, the tray, sliding rail, and supporting frame can be reinforced as part of the OEM customization process rather than treated as a separate product line. Buyers who expect to handle bariatric cases regularly should raise this at the quotation stage, since it affects internal chamber dimensions as well as tray strength.

Custom Mortuary Refrigerator Solutions

Standard models are available for common storage requirements. Customized products are developed by modifying existing configurations rather than creating an entirely new product from the beginning.

Available customization options include:

  • Number of storage chambers
  • Overall cabinet dimensions
  • Internal chamber dimensions
  • Front-opening or side-opening doors
  • Chamber arrangement
  • SUS304 or SUS201 stainless steel
  • Imported or Chinese-brand compressor
  • Voltage and frequency
  • Plug type
  • Alarm functions
  • Temperature recording functions
  • Door locks
  • Heavy-duty casters
  • Reinforced body trays
  • Customer logo and nameplate
  • Packaging and labeling

Customers should provide the required storage capacity, available installation space, door direction, local voltage, destination country and any tender specifications when requesting a quotation.

The company’s existing service information supports size- and function-based customization of mortuary and anatomy products.

Frequently Asked Questions

What is the operating temperature of a mortuary refrigerator?

The standard operating temperature is 2°C to 8°C (adjustable 0°C to 10°C).

The actual setpoint should follow the facility’s operating procedures, storage requirements and applicable local regulations.

What is the difference between a mortuary refrigerator and a mortuary freezer?

A mortuary refrigerator generally operates above freezing and is intended for controlled temporary storage.

A mortuary freezer operates at a sub-zero temperature and is intended for applications that require a lower storage temperature.

The required temperature range must be confirmed before ordering. Refrigerator and freezer temperature parameters should not be combined on the same product specification unless the equipment is specifically designed for both operating modes.

How many bodies can the refrigerator accommodate?

Standard configurations are available for 1, 2, 3, 4, 6, 8 and 9 bodies.

Two- and three-body side-opening models are also available. Customized chamber arrangements can be developed according to the customer’s facility.

What are the internal chamber dimensions?

The standard internal chamber dimensions are 1950 × 640 × 450 mm.

Custom internal dimensions are available for different body sizes, bariatric requirements or specific facility layouts.

Ready to Enhance Your Facility’s Capabilities?

Contact us today for a personalized quote on mortuary refrigerator solutions tailored to your capacity needs. Reach out via WhatsApp (+86-18309870034) or email (info@apsnesswellmedical.com). Let Aps Nesswell be your trusted partner for professional body storage refrigerator equipment.

Contact Us